http://WWW.INCREDIBLESOLUTION.CO
INCREDIBLESOLUTION 5634ad334ec0a42880916a11 False 504 60
OK
Description/ Specifi

Emerson Liebert 400D, 3*1 20KVA UPS

Products INR  290000 INR  255000
5b6b3b8e8c56630558a81607
size
  • S
  • M
  • L
qty
  • 1
  • 2
  • 3
Assured icon not found
True
CASH ON DELIVERY
SUBMIT A QUERY

Description/ Specification of 10/20KVA Online UPS Output parameters of 10/20KVA Online UPS: Capacity : 10 KVA / 8KW & 20KVA/16KW Power Factor : 0.8 Configuration : 1 phase, L-N + PE Nominal Voltage : 230 Vac Voltage Regulation : +/- 1% Voltage THD : <=2% - Linear load <=3% - Non linear load Frequency : 50 HZ Frequency Regulation - Free run frequency (Unsynchronised with bypass) : +/- 0.1 HZ Frequency Regulation (synchronised with bypass) : +/- 1,2, 3 HZ Creast Factor : 3:1 max. Transient response at 100% step load : +/- 10% Recovery time : <10 millisec Over load capacity : 150% - 60 seconds 125% - 10 minutes 110% - 60 minutes Parallel Redundancy : 1+1 INPUT PARAMETERS : Nominal Voltage : 415 Vac Voltage range : +25% and -30% Frequency : 50 HZ Frequency range- Hz : 45 to 55 HZ Power Factor : 1 (Unity) Current Distortion (I-THD) : <= 5% BYPASS : Voltage : 230 Vac Voltage Range : 207V to 253 Vac INBUILT BATTERY CHARGER : Maximum charging current : 4 Amp. EXTERNAL BATTERY CHARGER : NO Maximum charging current : BATTERY PARAMETERS : Type : SMF No. of battery blocks : 26 Battery Voltage : 312VDC Maximum Back up time at full load : 60 minutes /42AH ENVIRONMENTAL PARAMETERS : Operating temperature : 0 to 45 deg. centigrade Storage temperature : 0 to 70 deg. centigrade Relative Humidity : 95% RH Altitude : 1000 meters Noise level : <60db MECHANICAL PARAMETERS : Hight X width X Depth (MM) : 1150 X 450 X 650 Weight : 200 kg. /250Kg Protection : IP21 : Yes Sample Availability Supplier Product Code : S400D Competitive Advantages of the product Type of UPS : ON Line DSP/Micro processor based control : YES Wide input range : YES Input unity P.F. : YES Input I-THD - <5% : YES Functional with reverse phase sequence : YES Battery test facility : YES Temperature compenseted battery charger : YES Maximum Autonomy time 60 minutes Parallel Redundant : 1+1 Low output V-THD : YES Output isolation : YES LCD display : 4 line LCD display UPS parameters monitoring software : Multilink, MODBUS through OCWEB and OC-485

Availability: In Stock

Tags :

Billing Information

Order details QTY Total

Product Name 5b6b3b8e8c56630558a81607

Rs   2100

cancel
Note: Delivery usually takes 2.5 days, depending on availability and your location.
Order-Success icon not found

Your order has been placed successfully

Your order has been successfully placed. After it is reviewed, an email with the shipment details will be sent to the email ID you provided.
ok
order-failure icon not found

Your order could not be placed

Your order not be placed. Please try again at a later time.
ok
false