http://WWW.INCREDIBLESOLUTION.CO
INCREDIBLESOLUTION 5634ad334ec0a42880916a11 False 504 60
OK
SERVO CONTROLLED VOL

KRYKARD SERVO VOLTAGE STABLIGER 10KVA

Products INR  0 INR  0
5b6b3b8e8c56630558a81615
size
  • S
  • M
  • L
qty
  • 1
  • 2
  • 3
Assured icon not found
True
CASH ON DELIVERY
SUBMIT A QUERY

SERVO CONTROLLED VOLTAGE STABILISER Comprehensive Protection Applications  CNC machine tools  Injection Moulding machines  Textile machines ‐ Spinning, Weaving, Knitting, Embroidery, Garments manufacturing  Printing machines  Medical Equipment  Food Processing machines  Air Conditioning  1 phase Servo Stabilisers  2 phase Servo Stabilisers  3 phase input / 1 phase output Servo Stabilisers  3 phase Residential Servo Stabilisers  Isolation Transformer  Stabilisers with built‐in Isolation Transformers  Step up / Step down Transformers Microprocessor controlled Digital Voltage, Current & Frequency display Comprehensive protection Pan‐India sales & service network High‐efficiency Rugged design with high MTBF  Under / Over voltage trip ‐ The trip points can be set as per machine requirements  Electronic Overload trip ‐ CT based current sensing for accurate and reliable protection, activates beyond 110% of rated current, with programmable time delay to override inrush currents  Short TECHNICAL SPECIFICATIONS Parameter Rating (kVA) Type of cooling Input voltage range (V L-L) * Output voltage (V L-L) * 3 Phase Unbalanced Air cooled 3-150 Air 310-480 / 340-480 / 360-460 415 (380V/400V - optional) 3 Phase Unbalanced Oil cooled 3-2000 Oil Output Voltage Regulation Input frequency range Efficiency Effect of Load Power Factor Waveform Distortion Type of Servo Control Servo Motor Drive Under/ Over Voltage cutoff * Overload cutoff Short circuit protection Single phasing prevention Phase Reversal Trip Stabiliser bypass Transient Suppression Emergency Off Switch Frequency cut off protection Input High Voltage Trip Resetting mode Display Type Parameters displayed Parameters displayed LED indications Input / Output Terminations 1% of nominal output voltage 47Hz – 53Hz >97% Nil Nil Micro Controller based True RMS sensing and correction Triac based drive for AC Step Synchronous motor Electronic cutoff circuit with graded time delay, set @ +5% / -10% of nominal output voltage CT based Electronic cutoff circuit with graded time delay set @ 110% of rated full load current MCB / MCCB provided upto 100 kVA. For 125-200 kVA HRC fuse (MCCB optional) Provided Provided Provided up to 50 kVA 3-phase; Optional > 50 kVA Spike Suppression through MOV is provided (Surge Arrestor is optional) Provided Optional Optional Manual / Auto option provided with programmable time delay 2 Line LCD Panel Input & Output Voltages (Line & Phase), Output Currents & Frequency Fault Annunciation, Event Log Non Latching LED lamps for Input Present, Output Normal, MCB Trip, Stabiliser Bypass (if Bypass Switch is provided) DIN Connectors upto 100 kVA, Busbar or Bolted terminals for ratings >100 kVA

Availability: In Stock

Tags :

Billing Information

Order details QTY Total

Product Name 5b6b3b8e8c56630558a81615

Rs   2100

cancel
Note: Delivery usually takes 2.5 days, depending on availability and your location.
Order-Success icon not found

Your order has been placed successfully

Your order has been successfully placed. After it is reviewed, an email with the shipment details will be sent to the email ID you provided.
ok
order-failure icon not found

Your order could not be placed

Your order not be placed. Please try again at a later time.
ok
false