http://WWW.INCREDIBLESOLUTION.CO
INCREDIBLESOLUTION 5634ad334ec0a42880916a11 False 504 60
OK
background image not found
Found Update results for
'various brands'
5
Incredible Solution is Best UPS Supplier in Nahar Village, Rohini, New Delhi. It deals in various brands like Eaton UPS, APC UPS, Online UPS etc. To Visit http://incrediblesolution.co/
Incredible Solution is Best Battery Supplier in Nahar Village, Rohini, New Delhi. It deals in various brands like Amaron Battery, Rocket Battery, UPS Battery etc. To Visit http://incrediblesolution.co/
Incredible Solution is providing AMC for UPS of various brands. We believe in Service and Customer Satisfaction. To Visit http://incrediblesolution.co/
Emarson online ups Adapt Series 6-20kVA Applicable loads Equipment with extremely high requirement on voltage precision including server, storage, network equipment, ATM, VoIP, communication equipment, automation equipment, precision equipment, medical diagnosis equipment. Applications Small and medium-sized data/communication equipment room, network room, business operating room, lab, instrument room, control room, office space, charging center, precision control room, process control center. Product features Ultra high power density Extra wide input voltage/frequency range, adaptable to bad mains environment Up to 0.9 output power factor, supporting the electrical features of the latest server Efficiency of the system up to 92% ~94% Compatible with three-phase and single-phase, suitable for different applications Rack-mount/tower installation compatible Support parallel expended operation Provide rich rack options, easy for integration of switching/monitoring within the rack Can be connected to Emerson Optimize IT monitoring systemsmoothly Product positioning of Adapt series UPS?  Adapt series UPS is applicable to server room, etc., to protect key equipment including servers and network communication  Fully support Emerson Optimize IT integrated solution  Black body design reflects the harmonious matching with the server and cabinet How can Adapt series UPS ensure high reliable power supply?  Double-conversion online design, no interruption when AC mains fail  Support N+X redundant mode and realize highly increased system reliability  DSP full-digital control with high output voltage precision  Use the latest IGBT components to withstand big fluctuation of input mains voltage  Standard input anti-surge circuit with strong mains surge resistance How can Adapt series UPS protect the environment?  Good energy-saving performance with an overall efficiency of over 94%  Input power factor is up to 0.99 with high electric energy utility rate  Comply with EURoHS directives and the materials/manufacturing processes are free of poisonous substances  Adjustable speed intelligentfan with automatic speed adaptation effectively saves energy and reduces noise  Provide ECO operation mode with efficiency up to 98% and remarkable energy-saving performance How can Adapt series UPS save money for you?  Up to 0.9 output power factor, capable of powering more loads  Supportparallel expandedoperation, withoutthe needof complexparallel subrack  High system efficiency, power saving and low operational cost  High power density realizes smaller footprint of rack How can Adapt series UPS realize convenient maintenance?  Provide ultra-large LCD and LED display, so all kinds of operation data/system status/historical information is visible  Angle of the display panel can be adjusted freely according to different ways of installation, convenient and directly visible How can Adapt series UPS improve the reliability of solution?  Be compatible with three-single/single-single (6/10kVA) and three-single/three-three (16/20kVA) design and applicable to all kinds of applications  Support parallel operation, so the system capacity can be flexibly expanded  Backup time can be prolonged through cascaded connection How can Adapt series UPS meet various monitoring requirements?  Provide USB monitoring interface  Provide SIC card that can acquire environmental data and support auto-shutdown function of the server  Host computer software supports various operating systems such as Windows/ Linux/HP-UX/Sun Solaris/IBM AIX  Compatible with Emerson monitoring platform of SiteMonitor and supporting Web monitoring  Provide Mib database so the UPS can be connected to all kinds of NMS systems How Adapt series UPS protects and prolongs the battery life?  Extra-wide input voltage/frequency range effectively reduces the discharging times of the battery and prolongs the battery life  Temperature compensation function reduces influence of ambient temperature on the battery life  Extra strong charging capability effectively reduces the battery re-charging time  The number of battery sets can be arranged flexibly, facilitating utilization ofthe battery system (20kVA)  Support common batteries (20kAV) and save battery investment 10kVA 6kVA* *The sales product panel will change into this one after 2010, slightly different from the current one. Perfect energy savingandenvironmental friendly features  0.99 high input power factor improves the utility rate of electrical energy  Up to 94% system efficiency has remarkable energysaving performance  Comply with EU RoHS directives AC Power Systems for Business-Critical Continuity™ Adapt Series 6-20kVA Technical specifications List of optional parts 16-20kVA 16-20kVA Capacity 6kVA 10kVA 20kVA Standard model Long delay model Standard model Long delay model Long delay model Model UHA1R-0050 UHA1R-0050L UHA1R-0100 UHA1R-0100L UHA3R-0200L Input parameters Rectifier type IGBT rectifier Rated voltage 220/380Vac single-phase threewire/three-phase four-wire 220/380Vac single-phase threewire/three-phase four-wire 380Vac, three-phase four-wire Input voltage range single-phase 120Vac-276Vac single-phase 120Vac-288Vac three-phase 228Vac-478Vac Inputfrequency range 45Hz~55Hz 45Hz~65Hz 40Hz~70Hz Input power factor >=0.99 for Single-phase/>=0.95 for three-phase >0.99 at full load Battery Battery type Lead-acid maintenance-free battery Charging capability <3h for 90% re-charging of standard model <6h for 90% re-charging of standard model Max. charging power 4.5KW Battery backup time of standard model > 5 minutes No. of Battery 16 16 30 - 36 (Selected on site) Output parameters Rated power 6kVA/4.8KW 10kVA/9KW 20kVA/18KW Rated voltage Single-phase 220Vac Three-phase 380Vac,singlephase 220Vac Voltage precision 3% 1% Frequency precision 0.25% Output voltage THD <3% for linear load, <5% for non-linear load <2% for linear load, <5% for nonlinear load Load crestfactor 3:1(comply with IEC 62040-3) Step load performance 100% Output mode Terminal strip Overload performance (% of the rated load) 1min for 125% of the rated load 105%~125% 5mins, 125%~150% 1min, 500ms for over 150% 105%~125% 5mins, 125%~150% 1min, 200ms for over 150% System parameters and standard Conversion type Online double conversion Parallel mode Installation mode Rack-mount/tower compatible System efficiency > 3+1 1+1 1+1 92% >92.5% Up to 94% Switching time 0 ms Noise <50dB <55dB ≤58dB Language Chinese and English LCD display Yes (optional) Yes (standard) Safety IEC/EN62040-1-1 Electromagnetic compatibility IEC/EN 62040-2,IEC/EN61000-3-11,IEC/EN61000-3-12,YD/T1095-2008 Surge protection IEC/EN 62040-2, meeting IEC/EN61000-4-5 Protection level IP20 Dimensions (mm) 430× 625× 85 2U, 4U including battery 430× 625× 85 435× 640× 85 2U, 6U including battery 435× 640× 85 435× 750× 130 (3U) Net weight(Kg) 17 (without battery) 17.8 20.8 (without battery) 21.5 35 Warranty 1 year Communication and management Interface type USB/intelligent slot (dry contact card/SIC card/ Modbus card/RS485 card) Management software SiteMonitor Environmental parameters Operating temperature 0~+40˚ Relative humidity 5-95% without condensation Max. altitude <1500m(when the altitude exceeds 1500m, derating is required according to GB/T3859.2) < 2000m (when the altitude exceeds 2000m, derating is required according to GB/T3859.2) Name of optional part Remark Battery module 2U, suitable for 6 to 20kVA equipment, with sixteen 12V cells Optional communication parts SIC card Network monitoring SIC card, used for remote TCP/IP Web monitoring, supporting remote shutdown. It has expanded port to get access to temperature and humidity sensor Dry contact card Dry contact for UPS, providing four relay signal outputs and three discrete. Emerson online ups dealer in Delhi, Gurgaon and Noida.
Online UPS System is a true sine wave 4x4 parrelal combination that provide the clean power to your precise and mission critical equipment's, regardless of any disturbance on incoming AC power. The system offers many advance feature to give maximum reliability with flexibility of various configuration at the lower cost of electricity bills. With Incredible product you have complete peace of mind we are manufacturer in Delhi India.
1
false